Description

The World Housing Encyclopedia (WHE) Report Database contains 130 reports on housing construction types in 43 seismically active countries. Each housing report is a detailed description of a housing type in a particular country. The description is prepared from a number of standard closed-ended questions and some narrative that have been provided by report authors. Each report has five major categories including architectural and structural features; Building Materials and Construction Process; Socio-economic Issues; Past Performance In Earthquakes, Seismic Features and Vulnerability; and Retrofit. All of the housing reports in this database have been contributed by volunteers. If you are interested in writing a housing report please contact the WHE Editorial Board.

About

The World Housing Encyclopedia (WHE) is a collection of resources related to housing construction practices in the seismically active areas of the world. The mission is to share experiences with different construction types and encourage the use of earthquake-resistant technologies worldwide. The technical activities of the WHE are steered by an international team of 22 professionals specializing in different aspects of seismic safety of buildings and structures. They bring relevant experience from 16 seismically active countries across the world. For more information about the World Housing Encyclopedia, visit http://www.world-housing.net/.

General Information

 

Report #:67
Building Type: Popular, non-engineered urban housing on flat terrain
Country: Venezuela
Author(s): Argimiro Castillo Gandica
Francisco Lopez Almansa
Last Updated:
Regions Where Found: Buildings of this construction type can be found in Merida, Tachira and Trujillo, comprising the Andean states in Venezuela. This housing covers almost 40% of the total building stock in the city of M#rida. This type of housing construction is commonly found in urban areas.
Summary:

This is an urban housing construction type found in the ...

Length of time practiced: 25-60 years
Still Practiced: Yes
In practice as of:
Building Occupancy: Other
Typical number of stories: 2-3
Terrain-Flat: Typically
Terrain-Sloped: Off
Comments: 0.03 up to 0.05 meters typical separation distance between buildings


 

Features

 

 

Plan Shape Rectangular, solid
Additional comments on plan shape Typical shape of a building plan for this housing type is rectangular, with proportions (width/length) ranging from 1/3 to 1/4.
Typical plan length (meters) 12-15
Typical plan width (meters) 3-5
Typical story height (meters) 2.8
Type of Structural System Structural Concrete: Moment Resisting Frame: Designed for gravity loads only, with URM infill walls
Additional comments on structural system The vertical load-resisting system is reinforced concrete moment resisting frame. Reinforced concrete frames generally provide acceptable lateral load resistance, depending upon quality adequacy and upon the detailing of structural elements (columns and beams). In this case, several of the items are inadequate: the detailing of the reinforced concrete columns and beams, e.g., excessive stirrup spacing (same distance of element's section base); the tie anchorage (angle of anchorage is 90# instead of 135# as recommended in seismic codes); and the location of the laps in longitudinal reinforcement for columns (laps are provided at the bottom of columns in successive stories). The roof structure consists of lightweight roofing (zinc and/or acclimatized galvanized sheets) supported by I-shaped steel beams.
Gravity load-bearing & lateral load-resisting systems See Figure 2.
Typical wall densities in direction 1 >20%
Typical wall densities in direction 2 >20%
Additional comments on typical wall densities Two possibilities regarding wall density exist depending on position of the building in the block; there are Inner and Corner buildings Wall Density respectively. Wall density for Inner Buildings: Floor Number Total Wall Area longitudinal direction Total Wall Area transverse direction Typical Wall Density long. dir. Typical Wall Dens. trans. dir 1 114.24 56.96 1.28 0.64 2 119 64.72 1.33 0.62 Wall Density for Corner Buildings: Floor Number Total Wall Area longitudinal direction Total Wall Area transverse direction Typical Wall Density long. dir. Typical Wall Dens. trans. dir 1 108.48 56.96 1.21 0.64 2 114.2 64.72 1.28 0.72
Wall Openings Usually, openings are produced at the front and the back of the building, having door and window openings on the first level and two windows in successive levels. The openings range from 5 to 10% of the overall wall area.
Is it typical for buildings of this type to have common walls with adjacent buildings? No
Modifications of buildings Modifications respond to vertical growth, balconies, new windows, staircases for separate access to upper levels. Usually, when a new level is constructed, an external staircase facing the facade is built to permit separate access to upper levels. Windows and balconies are located in the facade and back walls. In lateral walls, windows are built when possible due to lateral proximity between buildings.
Type of Foundation Shallow Foundation: Reinforced concrete isolated footing
Additional comments on foundation See Figure 2
Type of Floor System Other floor system
Additional comments on floor system Composite hollow clay tiles and steel joists; Floors may be considered as rigid diaphragms. Special inspection must be performed on floor connection with beams, to guarantee transmission of lateral loads.
Type of Roof System Roof system, other
Additional comments on roof system Steel joists and metal sheathing (zinc/aluminum); Roof may not be considered as a rigid diaphragm, due to the reduced sections (at most IPN 80), the low connectivity between joists and the lack of connection with the rest of the structure (absence of a collar beam on top of walls in roof level).
Additional comments section 2 When separated from adjacent buildings, the typical distance from a neighboring building is 0.03-0.05 meters.

 

Building Materials and Construction Process

 

 

Description of Building Materials


Structural Element Building Material (s)Comment (s)
Wall/Frame Wall: Hollow Clay Tile, Cement Mortar Frame: Reinforced ConcreteCharacteristic Strength: Cement mortar 3.0 MPa Mix Proportion/Dimensions: W/H/L (mm.)100/250/350120/250/350150/200/350200/200/350 N/A
Foundations Reinforced ConcreteMix Proportion/Dimensions: W/H/L (mm.)1000/400/1000
Floors Clay tiles Steel joists Characteristic Strength: N/A Structural Steel Mix Proportion/Dimensions: W/H/L (mm.)60/350/60060/350/800 IPN 80(h: 80mm)IPN100(h:100mm)
Roof Steel Joists Ties Metal sheathing (zinc/aluminum) Characteristic Strength: Steel Mild steel Mix Proportion/Dimensions: IPN 80 (h:80mm) 2x1 inches W/L (mm.)830/4000
Other

Design Process


Who is involved with the design process? Other
Roles of those involved in the design process As an auto-constructed type, construction professionals (Architects and/or Engineers) are not involved in the design or in the construction process. Professional intervention is unaffordable for the inhabitants of these settlements.
Expertise of those involved in the design process No professionals (Architects and/or Engineers) are involved in the design or construction process.

Construction Process


Who typically builds this construction type? Other
Roles of those involved in the building process The builder lives in this construction type.
Expertise of those involved in building process Builders mainly count on some experience in building construction. Semi-skilled level seems to suit adequately the expertise of the builders.
Construction process and phasing Construction process is performed in vertical phases, i.e. a level at a time. Common practice is to build foundations and columns for the first level, leaving columns longitudinal steel bars to be spliced. After concrete curing, the walls are built. Beams are built over walls, and afterwards the first slab (hollow clay tiles with steel joists) is constructed. The owner typically builds with no more than two helpers. The entire process is performed at the building site with ordinary building tools; no special machinery or equipment is used. The construction of this type of housing takes place incrementally over time. Typically, the building is originally not designed for its final constructed size. Construction phasing depends on the availability of money. These resources are obtained from savings and from the cooperation of other family members. Usually the inhabitants collaborate in the building process.
Construction issues

Building Codes and Standards


Is this construction type address by codes/standards? No
Applicable codes or standards
Process for building code enforcement Official authorities have no process or strategy for building code enforcement.

Building Permits and Development Control Rules


Are building permits required? No
Is this typically informal construction? Yes
Is this construction typically authorized as per development control rules? No
Additional comments on building permits and development control rules

Building Maintenance and Condition


Typical problems associated with this type of construction Inexistent seismic detailing features in reinforced concrete works. Connections between floors and structural frames do not guarantee lateral force transmission and may induce displacement of slabs with respect to the frames generating damage to columns. Parapets in uppermost levels represent a dangerous collapsible feature. The absence of collar beams and horizontal reinforcement in uppermost walls may produce out-of-plane inertial loads. Gap between adjacent buildings (not greater than 10.0 cm.) creates risk of pounding effect.
Who typically maintains buildings of this type? Owner(s)
Additional comments on maintenance and building condition

Construction Economics


Unit construction cost Unit construction cost: 87000 Bs. (120 US$) per square meter of built-up area.
Labor requirements For each level, with a three worker team, 45 to 55 days are required to complete the construction.
Additional comments section 3

 

Socio-Economic Issues

 

 

Patterns of occupancy The number of families depends mostly upon the number of levels (e.g. two levels, two families). An average occupancy pattern is two families (5.40 members/family). Each building typically has 2 housing unit(s). This is an estimate of the average number of housing units per building.
Number of inhabitants in a typical building of this construction type during the day <5
Number of inhabitants in a typical building of this construction type during the evening/night 10-20
Additional comments on number of inhabitants
Economic level of inhabitants Low-income class (poor)
Additional comments on economic level of inhabitants Annual income ranges from $2000-$3000 Currency: US $ Economic Level: For Poor Class the Housing Price Unit is 31000 and the Annual Income is 2500. Ratio of housing unit price to annual income: 5:1 or worse
Typical Source of Financing Owner financedPersonal savings
Additional comments on financing
Type of Ownership Own outright
Additional comments on ownership
Is earthquake insurance for this construction type typically available? No
What does earthquake insurance typically cover/cost
Are premium discounts or higher coverages available for seismically strengthened buildings or new buildings built to incorporate seismically resistant features? No
Additional comments on premium discounts
Additional comments section 4

 

Earthquakes

 

 

Past Earthquakes in the country which affected buildings of this type


YearEarthquake Epicenter Richter Magnitude Maximum Intensity
199710.5N 5.3#W Depth 9.4 km(Car#aco, Venezuela)
6.8VIII (MMI)

Past Earthquakes


Damage patterns observed in past earthquakes for this construction type See Figure 6.
Additional comments on earthquake damage patterns Wall: Cracks in walls, parts of walls collapse, great cracks in windows and around doors. Frame: Shear failure in connections between columns and beams, and between columns and foundations, excessive lateral displacements, cracking and spalling concrete columns due to inadequate confinement. Roof/Floors: Roof- great movements may be generated in roofs, total dismantlement and consequent collapse may occur. Floors- great movements may inflict damage in confinement and walls. Other: Column failure at level where slabs of neighboring construction pounds.

Structural and Architectural Features for Seismic Resistance


The main reference publication used in developing the statements used in this table is FEMA 310 “Handbook for the Seismic Evaluation of Buildings-A Pre-standard”, Federal Emergency Management Agency, Washington, D.C., 1998.

The total width of door and window openings in a wall is: For brick masonry construction in cement mortar : less than ½ of the distance between the adjacent cross walls; For adobe masonry, stone masonry and brick masonry in mud mortar: less than 1/3 of the distance between the adjacent cross walls; For precast concrete wall structures: less than 3/4 of the length of a perimeter wall.
Structural/Architectural Feature Statement Seismic Resistance
Lateral load pathThe structure contains a complete load path for seismic force effects from any horizontal direction that serves to transfer inertial forces from the building to the foundation.FALSE
Building Configuration-VerticalThe building is regular with regards to the elevation. (Specify in 5.4.1)TRUE
Building Configuration-HorizontalThe building is regular with regards to the plan. (Specify in 5.4.2)TRUE
Roof ConstructionThe roof diaphragm is considered to be rigid and it is expected that the roof structure will maintain its integrity, i.e. shape and form, during an earthquake of intensity expected in this area.FALSE
Floor ConstructionThe floor diaphragm(s) are considered to be rigid and it is expected that the floor structure(s) will maintain its integrity during an earthquake of intensity expected in this area.FALSE
Foundation PerformanceThere is no evidence of excessive foundation movement (e.g. settlement) that would affect the integrity or performance of the structure in an earthquake. TRUE
Wall and Frame Structures-RedundancyThe number of lines of walls or frames in each principal direction is greater than or equal to 2.TRUE
Wall ProportionsHeight-to-thickness ratio of the shear walls at each floor level is: Less than 25 (concrete walls); Less than 30 (reinforced masonry walls); Less than 13 (unreinforced masonry walls);FALSE
Foundation-Wall ConnectionVertical load-bearing elements (columns, walls) are attached to the foundations; concrete columns and walls are doweled into the foundation.TRUE
Wall-Roof ConnectionsExterior walls are anchored for out-of-plane seismic effects at each diaphragm level with metal anchors or straps. FALSE
Wall OpeningsFALSE
Quality of Building MaterialsQuality of building materials is considered to be adequate per the requirements of national codes and standards (an estimate). FALSE
Quality of WorkmanshipQuality of workmanship (based on visual inspection of a few typical buildings) is considered to be good (per local construction standards).FALSE
MaintenanceBuildings of this type are generally well maintained and there are no visible signs of deterioration of building elements (concrete, steel, timber).FALSE

Additional comments on structural and architectural features for seismic resistance
Vertical irregularities typically found in this construction type Other
Horizontal irregularities typically found in this construction type Other
Seismic deficiency in walls No reinforcement is visible throughout the walls (neither horizontal nor vertical). Poor quality mortar and cracked masonry units.
Earthquake-resilient features in walls
Seismic deficiency in frames -Stirrup and tie spacing is not compliant to recommendations of less than d/2 spacing in beams and d/4 in columns, neither in beams nor in columns. Spacing is regular throughout all members and is usually d or more. Anchorage hooks into member cores are g
Earthquake-resilient features in frame
Seismic deficiency in roof and floors Roof may not be considered as a rigid diaphragm due to the lack of adequate connectivity within its elements and with the walls (absence of a collar beam on top of walls at this level).Connections between floor and frames must be inspected to guarantee adequate linking and load transmission.
Earthquake resilient features in roof and floors
Seismic deficiency in foundation
Earthquake-resilient features in foundation

Seismic Vulnerability Rating


For information about how seismic vulnerability ratings were selected see the Seismic Vulnerability Guidelines

High vulnerabilty Medium vulnerabilityLow vulnerability
ABCDEF
Seismic vulnerability class |- o -|

Additional comments section 5 See Figures 4 and 5.

Retrofit Information

 

Description of Seismic Strengthening Provisions


Structural Deficiency Seismic Strengthening

Additional comments on seismic strengthening provisions For the moment, seismic strengthening provisions have not been performed, either in design or in retrofitting.
Has seismic strengthening described in the above table been performed? No
Was the work done as a mitigation effort on an undamaged building or as a repair following earthquake damages?
Was the construction inspected in the same manner as new construction?
Who performed the construction: a contractor or owner/user? Was an architect or engineer involved?
What has been the performance of retrofitted buildings of this type in subsequent earthquakes?
Additional comments section 6

 

References

"Basic Concepts of Seismic Codes, Vol.1, Part I, Non- Engineered Construction", IAEE, 1980.


#Evaluaci#n preliminar del sismo de Car#aco del 9 de Julio de 1997, Estado Sucre, Venezuela (Versi#n Revisada)#, FUNVISIS (Fundaci#n Venezolana de Investigaciones Sismol#gicas), Caracas, Octubre 1997.


FEMA 310 Handbook for the Seismic Evaluation of Buildings: A Pre-standard Federal Emergency Management Agency, Washington, D.C. 1998


Authors



Name Title Affiliation Location Email
Argimiro Castillo Gandica University Professor University of The Andes Av. Mistral 73-75, 3ro 2da, Barcelona 08015 Spain argimirocastillo@icnet.com.ve
Francisco Lopez Almansa University Professor Polytechnic University of Catalonia Estructuras en la Arquitectura, Av. Diagonal, 649 08028 Spain francesc.lopez@ea.upc.es

Reviewers


Name Title Affiliation Location Email
Sergio Alcocer Director of Research Circuito Escolar Cuidad Universitaria, Institute of Engineering, UNAM Mexico DF 4510, MEXICO salcocerm@iingen.unam.mx