Description

The World Housing Encyclopedia (WHE) Report Database contains 130 reports on housing construction types in 43 seismically active countries. Each housing report is a detailed description of a housing type in a particular country. The description is prepared from a number of standard closed-ended questions and some narrative that have been provided by report authors. Each report has five major categories including architectural and structural features; Building Materials and Construction Process; Socio-economic Issues; Past Performance In Earthquakes, Seismic Features and Vulnerability; and Retrofit. All of the housing reports in this database have been contributed by volunteers. If you are interested in writing a housing report please contact the WHE Editorial Board.

About

The World Housing Encyclopedia (WHE) is a collection of resources related to housing construction practices in the seismically active areas of the world. The mission is to share experiences with different construction types and encourage the use of earthquake-resistant technologies worldwide. The technical activities of the WHE are steered by an international team of 22 professionals specializing in different aspects of seismic safety of buildings and structures. They bring relevant experience from 16 seismically active countries across the world. For more information about the World Housing Encyclopedia, visit http://www.world-housing.net/.

General Information

 

Report #:53
Building Type: Small concrete block masonry walls with concrete floors and roofs
Country: Russia
Author(s): Mark Klyachko
Yuriy Gordeev
Freda Kolosova
Last Updated:
Regions Where Found: Buildings of this construction type can be found in seismically prone areas of Russia (Far East, Siberia, Baikal Lake Region, North Caucasus) and CIS states (Central Asia, Armenia, Georgia, etc.) where it accounts for 10 to 15% of the housing stock.
Summary:

This is a typical residential construction found both in urban ...

Length of time practiced: 25-60 years
Still Practiced: Yes
In practice as of:
Building Occupancy: Residential, 20-49 units
Typical number of stories: 2-4
Terrain-Flat: Typically
Terrain-Sloped: Occasionally
Comments: This is the Soviet Union construction practice followed during the last 50-60 years (after the Second World War). Building Occu


 

Features

 

 

Plan Shape Rectangular, solid
Additional comments on plan shape In general all building plans are of rectangular shape.
Typical plan length (meters) 43
Typical plan width (meters) 12
Typical story height (meters) 2.7
Type of Structural System Masonry: Unreinforced Masonry Walls: Concrete block masonry in cement mortar
Additional comments on structural system Lateral Load-Resisting System: Lateral load-resisting system consists of concrete block masonry walls and precast reinforced floor structure. In most cases floor structure consists of the precast reinforced concrete hollow core panels, which are combined in horizontal diaphragm by means of cast-in-situ reinforced concrete bond beams (belt) constructed at the building perimeter. Gravity Load-Bearing Structure: Same as lateral load-resisting system.
Gravity load-bearing & lateral load-resisting systems
Typical wall densities in direction 1 >20%
Typical wall densities in direction 2 >20%
Additional comments on typical wall densities The typical structural wall density is more than 20 %. 20-25%.
Wall Openings Windows: 10-15%; Doors: 5-8%.
Is it typical for buildings of this type to have common walls with adjacent buildings? No
Modifications of buildings Typical modification patterns include the demolition of interior walls and perforation of walls with door openings.
Type of Foundation Shallow Foundation: Reinforced concrete strip footing
Additional comments on foundation
Type of Floor System Other floor system
Additional comments on floor system Precast hollow core concrete slabs
Type of Roof System Roof system, other
Additional comments on roof system Precast hollow core concrete slabs
Additional comments section 2 In hilly areas from 1.5% to ~15%; on the flat terrain approximately 85% When separated from adjacent buildings, the typical distance from a neighboring building is 5 meters.

 

Building Materials and Construction Process

 

 

Description of Building Materials


Structural Element Building Material (s)Comment (s)
Wall/Frame Masonry Steel Concrete Characteristic Strength Masonry: 50 kg/m.sq. (compressive strength) Steel: 295 MPa (Steel yield strength) Concrete: 20-30 MPa (cube compressive strength)
Foundations ConcreteCharacteristic Strength: 10-15 MPa (cube compressive strength) 295 MPa (Steel yield strength)
Floors Slabs # reinforced concreteCharacteristic Strength: 30 MPa (cube compressive strength) 295 MPa (Steel yield strength)
Roof Slabs # reinforced concreteCharacteristic Strength: 30 MPa (cube compressive strength) 295 MPa (Steel yield strength)
Other

Design Process


Who is involved with the design process? EngineerArchitect
Roles of those involved in the design process Design performed by Professional Engineers and Architects.
Expertise of those involved in the design process Expertise for design of buildings of this type was available, including the construction quality procedure developed by the author of this contribution.

Construction Process


Who typically builds this construction type? Other
Roles of those involved in the building process Buildings of this type were built by government-owned construction companies.
Expertise of those involved in building process
Construction process and phasing All precast structure members and concrete blocks are manufactured in special construction plants. Masonry mortar is usually produced in the factory, too. Lifting crane is used for the erection of the building. The construction of this type of housing takes place in a single phase. Typically, the building is originally designed for its final constructed size.
Construction issues

Building Codes and Standards


Is this construction type address by codes/standards? Yes
Applicable codes or standards Code/Standard: Building Catalog of Typical Project for housing seria of 1-306c, 1-307c, 1957y, issued1951 The year the first code/standard addressing this type of construction issued was 1951. Construction in the Seismic Regions. SNiP II-7-81*. The most recent code/standard addressing this construction type issued was 1981. Afterward, numerous amendments were introduced.
Process for building code enforcement The process consists of issuing permits for the design & construction, including the architectural permits and urban planning/municipal permits. Designers need to have licence to practice and are responsible to follow the building codes. Building inspection is performed and the permit is issued.

Building Permits and Development Control Rules


Are building permits required? Yes
Is this typically informal construction? No
Is this construction typically authorized as per development control rules? Yes
Additional comments on building permits and development control rules

Building Maintenance and Condition


Typical problems associated with this type of construction Use of rigid mortars in the construction and a low cohesion in the masonry.
Who typically maintains buildings of this type? Owner(s)
Additional comments on maintenance and building condition The maintenance is performed either by the owner (city) or (periodically) by a contractor # a maintenance firm.

Construction Economics


Unit construction cost 250-350 $US/sq m (per the official rate).
Labor requirements It takes about 30 man-months to build a 4-story building with plan dimensions 12m x 42m.
Additional comments section 3

 

Socio-Economic Issues

 

 

Patterns of occupancy One family per unit (apartment). Each building typically has 36 housing unit(s). Usually there are 12 - 36 units in each building.
Number of inhabitants in a typical building of this construction type during the day 10-20
Number of inhabitants in a typical building of this construction type during the evening/night >20
Additional comments on number of inhabitants
Economic level of inhabitants Very low-income class (very poor)Low-income class (poor)Middle-income class
Additional comments on economic level of inhabitants Ratio of housing unit price to annual income: 1:1 or better
Typical Source of Financing Government-owned housing
Additional comments on financing
Type of Ownership Own outrightLong-term lease
Additional comments on ownership Own outright (for unit); Long-term lease (most common)
Is earthquake insurance for this construction type typically available? Yes
What does earthquake insurance typically cover/cost The insurance is available as a part of the usual property insurance. Insurance typically covers about 3-5% of the total estimated property value.
Are premium discounts or higher coverages available for seismically strengthened buildings or new buildings built to incorporate seismically resistant features? No
Additional comments on premium discounts
Additional comments section 4 It is not common that owners purchase earthquake insurance.

 

Earthquakes

 

 

Past Earthquakes in the country which affected buildings of this type


YearEarthquake Epicenter Richter Magnitude Maximum Intensity
1959Kamchatka, Russia
1971Kamchatka, Russia
1988Spitak, Armenia
7.88(MSK)
7.27(MSK)
6.99(MSK)

Past Earthquakes


Damage patterns observed in past earthquakes for this construction type Some buildings of this type were damaged in the 1959 and 1971 Kamchatka earthquakes and 1988 Spitak earthquake.
Additional comments on earthquake damage patterns

Structural and Architectural Features for Seismic Resistance


The main reference publication used in developing the statements used in this table is FEMA 310 “Handbook for the Seismic Evaluation of Buildings-A Pre-standard”, Federal Emergency Management Agency, Washington, D.C., 1998.

The total width of door and window openings in a wall is: For brick masonry construction in cement mortar : less than ½ of the distance between the adjacent cross walls; For adobe masonry, stone masonry and brick masonry in mud mortar: less than 1/3 of the distance between the adjacent cross walls; For precast concrete wall structures: less than 3/4 of the length of a perimeter wall.
Structural/Architectural Feature Statement Seismic Resistance
Lateral load pathThe structure contains a complete load path for seismic force effects from any horizontal direction that serves to transfer inertial forces from the building to the foundation.FALSE
Building Configuration-VerticalThe building is regular with regards to the elevation. (Specify in 5.4.1)TRUE
Building Configuration-HorizontalThe building is regular with regards to the plan. (Specify in 5.4.2)TRUE
Roof ConstructionThe roof diaphragm is considered to be rigid and it is expected that the roof structure will maintain its integrity, i.e. shape and form, during an earthquake of intensity expected in this area.TRUE
Floor ConstructionThe floor diaphragm(s) are considered to be rigid and it is expected that the floor structure(s) will maintain its integrity during an earthquake of intensity expected in this area.TRUE
Foundation PerformanceThere is no evidence of excessive foundation movement (e.g. settlement) that would affect the integrity or performance of the structure in an earthquake. TRUE
Wall and Frame Structures-RedundancyThe number of lines of walls or frames in each principal direction is greater than or equal to 2.TRUE
Wall ProportionsHeight-to-thickness ratio of the shear walls at each floor level is: Less than 25 (concrete walls); Less than 30 (reinforced masonry walls); Less than 13 (unreinforced masonry walls);TRUE
Foundation-Wall ConnectionVertical load-bearing elements (columns, walls) are attached to the foundations; concrete columns and walls are doweled into the foundation.TRUE
Wall-Roof ConnectionsExterior walls are anchored for out-of-plane seismic effects at each diaphragm level with metal anchors or straps. TRUE
Wall OpeningsTRUE
Quality of Building MaterialsQuality of building materials is considered to be adequate per the requirements of national codes and standards (an estimate). FALSE
Quality of WorkmanshipQuality of workmanship (based on visual inspection of a few typical buildings) is considered to be good (per local construction standards).FALSE
MaintenanceBuildings of this type are generally well maintained and there are no visible signs of deterioration of building elements (concrete, steel, timber).FALSE

Additional comments on structural and architectural features for seismic resistance
Vertical irregularities typically found in this construction type Other
Horizontal irregularities typically found in this construction type Other
Seismic deficiency in walls -Absence of lime and plastifier; -Low cohesion of masonry (<120 kPa); (cohesion is equal to tension strength of masonry when shear stress=0). -Low-strength masonry and cement mortar.
Earthquake-resilient features in walls
Seismic deficiency in frames
Earthquake-resilient features in frame
Seismic deficiency in roof and floors #NAME?
Earthquake resilient features in roof and floors
Seismic deficiency in foundation
Earthquake-resilient features in foundation

Seismic Vulnerability Rating


For information about how seismic vulnerability ratings were selected see the Seismic Vulnerability Guidelines

High vulnerabilty Medium vulnerabilityLow vulnerability
ABCDEF
Seismic vulnerability class o -|

Additional comments section 5

Retrofit Information

 

 

Description of Seismic Strengthening Provisions


Structural Deficiency Seismic Strengthening
Inadequate seismic resistance of masonry walls The method of exterior frame - see Additional Comments
Inadequate seismic resistance of masonry walls Vertical post-tensioning; see Additional Comments and Figures 9 and 10.
Inadequate seismic resistance of masonry walls The method of added stiffness (reinforced concrete overlay); see Additional Comments and Figures 11 and 12.
Inadequate seismic resistance of masonry walls Strengthening using the "Upper Damping Storey" method

Additional comments on seismic strengthening provisions The recommended methods for seismic strengthening of buildings of this construction type are: METHOD OF EXTERIOR FRAME (MEF) Goal: To increase lateral seismic stability of buildings with load-bearing masonry or large-block concrete walls. Concept: The system of precast or "cast-in-situ" concrete buttresses (counterforts) (1) tied to the longitudinal exterior wall. Application: This method has been used successfully for seismic strengthening of buildings with longitudinal bearing walls and deficient lateral earthquake resistance both as self-contained strengthening system and as a combination with PTS (for stringer walls) or with SIS (for extended masonry buildings with widely spaced lateral inner walls). Description: The MEF is performed by constructing special concrete buttresses (counterforts) tied to the longitudinal load-bearing walls at the building ends and other locations as required. In order to ensure a uniform seismic performance of the existing structure strengthened with the buttresses, the buttresses are tied to the existing walls by means of the dowels and anchors. This solution does not require the pairs of buttresses (counterforts) to be tied at each floor level; it is considered to be adequate to install a prestressed tie to connect the buttresses (counterforts) at the roof level. STRENGTHENING OF BUILDINGS USING THE POST # TENSIONING SYSTEM (PTS) Goal: To increase seismic resistance of existing buildings. Concept: The reduction in principal tensile stresses induced by seismic loads to allowable levels. Description and sequence of operations: -Drilling of the vertical holes is carried out by means of special equipment; the amount of opening (10) is not less than one for each partition. -The wire cables (2) are pulled through each opening (10). -Cables are anchored at the basement level and then post-tensioned up to 1600 KN. -A special cement-based grout (1) is injected into the holes and the cables are subsequently anchored at the roof level. The post-tensioning of walls prevents the formation of cracks in an earthquake and results in the increased seismic resistance of the indivdual walls and the building as a whole. Equipment: For drilling: "GEARMEC" (Sweden); for post-tensioning: IMS system (Yugoslavia). THE METHOD OF ADDED STIFFNESS (SIS) Goal: Seismic strengthening of masonry buildings to achieve increased seismic reliability and safety. Concept: The stiffness increase is achieved by means of a new reinforced concrete wall (overlay) attached to the existing wall. In this way, the coupled perforated shear walls are formed, and lateral seismic loads are redistributed: the seismic loads remove on the spine walls from principal one. Description: The SIS method consists of constructing new cast-in-situ concrete walls (1) of 10-15 cm thickness reinforced with steel wire mesh. The new walls are attached to the existing ones using dowels (3) and anchors (4). The new walls may be constructed with additional pilasters (2) if required. Equipment: Sheathing "MEVA" (Germany), instruments: "Bosch" and "Hilti" (Germany). THE METHOD OF UPPER DAMPING STOREY (UDS) Goal: To develop a big mass damper for the self-damping of buildings under seismic impact. Concept: To achieve a flexible structure with stiffness and mass capable of reducing the seismic demand in an existing building to a permissible level. Application: Masonry or block buildings with deficient seismic resistance D=2.0 (MSK scale). A very effective application for 4- to 5-story residential masonry and large-block houses with D=1.0-1.5. The superstructure can be constructed as a "cold" garret or as additional floor (duplex apartment).
Has seismic strengthening described in the above table been performed? Yes. A number of buildings of this type have been strengthened using the above described methodology.
Was the work done as a mitigation effort on an undamaged building or as a repair following earthquake damages? In most cases repair was executed after earthquake damage.
Was the construction inspected in the same manner as new construction? Yes
Who performed the construction: a contractor or owner/user? Was an architect or engineer involved? Strengthening of buildings is accomplished by contractor. All processes are controlled by engineers.
What has been the performance of retrofitted buildings of this type in subsequent earthquakes? N/A
Additional comments section 6

 

References

Manual on Certification of Buildings and Structures in the Seismic-Prone Areas, Second Edition, CENDR, Petropavlovsk, Kamchatka, Russia, 1990.


Recommendations for Preventive Seismic Strengthening of Buildings, CENDR, Russia, 1993



Authors




Name Title Affiliation Location Email
Mark Klyachko Dr./ Director Centre on EQE&NDR, (CENDR) 9 Pobeda Ave., Petropavlovsk, Kamchatka cendr@svyaz.kamchatka.su
Yuriy Gordeev Head of Dept. Centre on EQE&NDR, (CENDR) 9 Pobeda Ave., Petropavlovsk, Kamchatka cendr@svyaz.kamchatka.su
Freda Kolosova Head of Dept. Centre on EQE&NDR, (CENDR) 9 Pobeda Ave., Petropavlovsk, Kamchatka cendr@svyaz.kamchatka.su

Reviewers


Name Title Affiliation Location Email
Svetlana Uranova Head of the Laboratory KRSU Bishkek 720000, KYRGYZSTAN uransv@yahoo.com